Model |
CTU-8-CVSeries |
CTL-CLS-CV
Series |
CTD-10 |
CTD-20 |
Shape |
|
|
|
|
Features/Application |
AC mean
Current to DC
voltage convertor
Through hole Type |
AC mean Current to DC
voltage convertor
Clamp On Type |
AC RMS
Current to DC
convertor |
All round
Current to DC
convertor |
Dimension (mm) |
60W x 25D x 37H |
Same as Clamp on CT |
24W x 96D x 60H |
48W x 96D x 100H |
Current Range |
0-10A
0-20A
0-30A
0-50A
4 Types |
0-5A
0-50A
0-100A
0-250A
0-500A
5 Types |
1 ~ 16A
(1A step)
20 ~ 320A
(20A step)
Progrmable |
DC-20KHz
10 ~ 800Arms |
Max Current |
200% (cont) |
150% (1MIN) |
120% (cont) |
250% (cont) |
OUT PUT |
0-5V
Voltage signal
Response: 0.1 ~ 0.2S |
0-5V
Voltage signal
Response: 0.3S |
0-5V, 4-20mA
2WAY signal
Response: 20ms |
0-5V, 4-20mA
2WAY signal
Response: 20ms |
Attached sensor |
All in One structure |
AC Current Sensor
CTL-CLS Series
(3000 Turns) |
DC Current
Sensor
HCS-HP series |
Remarks |
No Control Power Supply
Suitable for AC-50/60HZ
Sinewave Current |
AC85 ~ 250V
Wide Power Supply
Suitable for
AC-50/60HZ
any waveform |
AC85 ~ 250V
Wide Power
Supply
Suitable for
DC-20KHZ
any waveform |